Lattice structure tensile specimen manufactured with laser melting (LM) process out of the material H13. Show image information
Industry partners of the DMRC. Show image information
Industry partners of the DMRC. Show image information
Quality control during a Laser Sinter (LS) build job by a researcher of the DMRC. Show image information
Fused Deposition Modeling (FDM) process during the manufacture of an Ultem 9085 part. Show image information
Additive manufactured reaction wheel bracket for telecomunication satellites. Show image information
Employees of the DMRC working with the "freeformer" from Arburg. Show image information
Tactile measurement of a SLM part with a Coordinatemeasuring machine (CMM). Show image information

Lattice structure tensile specimen manufactured with laser melting (LM) process out of the material H13.

Industry partners of the DMRC.

Industry partners of the DMRC.

Quality control during a Laser Sinter (LS) build job by a researcher of the DMRC.

Fused Deposition Modeling (FDM) process during the manufacture of an Ultem 9085 part.

Additive manufactured reaction wheel bracket for telecomunication satellites.

Employees of the DMRC working with the "freeformer" from Arburg.

Tactile measurement of a SLM part with a Coordinatemeasuring machine (CMM).

Physical and chemical analysis

 

Moisture measurement AQUATRAC, Brabender Messtechnik GmbH

  • Measuring principle: chemical reaction with calcium hydride
  • Able to detect moisture of less than 0.01% H2O
  • Sample weight: 0.1 - 100 g
  • Test temperature: 80 °C - 200 °C
  • Test time: 10 - 45 min
  • Measurement accuracy: +2% of reading, +1% of range
  • Reproductibility: approx. + 1% of reading

DSC Analysis – Netzsch DSC 214 Polyma

  • Temperature range 25…600 °C
  • 3 MFCs for purge and protective gases
  • Current purge with nitrogen, oxygen and/or air (other gases available)
  • Resolution 0,1 µW
  • Heating/cooling rate 0,001…500 K/min (dependent on temperature)
  • Static and dynamic thermal analyses
  • OIT analysis
  • Add-on for heat capacity analysis

Precision balance CPA224s, Satorius AG

  • Weighing capacity: 220 g
  • Readability: 0,1 mg
  • Repeatability: ≤± 0,1 mg
  • Minimum sample weight: 120 mg
  • Pan size: Ø 80 mm

Broadbrand dielectric spectrometer, Novocontrol GmbH

  • Frequency range: 3 μHz - 40 MHz
  • Temperature range: -160 °C - +400 °C

Rheometer, Physica MCR 501, Anton Paar GmbH

  • Measuring range: 0,01 µNm - 230 mNn / 10-5 - 628 Hz /  0,01 - 50 N
  • Temperature range: -100 - +350 °C
  • Measuring chamber for DMA / DTMA

Extrusion plastometer Mflow, Zwick

  • Measuring range: 50 - 450 °C
  • Load: max 21,6 kg
  • Methods: MVR or MFI

Sputter Coater SC7620, Polaron

  • Sputter targets: Gold/Palladium
  • Chamber size: Ø 100 mm, height: 100 mm
  • Max. vacuum: 2 x 10-2 mbar
  • Gas: Argon
Contact

Stephan Tölle

DMRC

Laboratory Engineer

Stephan Tölle
Phone:
+49 5251 60-5413
Fax:
+49 5251 60-5409
Office:
W0.106